The specific limitations will depend on the printer used. These are our generic guidelines for our parts-printing service, which are common for COR printed on typical 385nm DLP systems.
| Feature Type | Size |
|---|---|
| Unsupported Wall Thickness | 2.5 mm |
| Supported Wall Thickness | 1.25 mm |
| Maximum Horizontal Bridge | 3 mm |
| Unsupported Angle From Horizontal | 30 ° |
| XY Hole Size | 1 mm |
| Z Hole Size | 1 mm |
The polySpectra team can help with application-specific design requirements, including microfluidic channels, thin-walled dental and medical devices, and electronics connectors. Please contact partners@polyspectra.com if you have special design restrictions.